TWiki
>
DetDev Web
>
ResearchResults
>
MCMD
>
IVCV
(2008-12-16,
LarsEklund
)
(raw view)
E
dit
A
ttach
---+ IV and CV measurments Measurements performed by Alex Chilingarov, University of Lancaster and analysis is done by Lars Eklund, University of Glasgow. ---++++ *Summary plots of I/V and C/V performance for wafer 09 (12 µm BCB)* The scale of the I/V graph covers the range of 25 of the 26 sensors on wafer 09. Sensor X5Y3 breakes down at low voltages, see [[%ATTACHURL%/X5Y3_IVgraph.gif][separate I/V]]. Sensors X5Y1, X5Y2 and X5Y4 were ramped to 600 V with leakage current of 40, 33 and 31 nA at 600V. Sensor X5Y1 was kept at 600 V for 30 min and is the only sensor that shows a clear change in reverse current over time, but with signs of saturation. See [[%ATTACHURL%/X5Y1_biasStability.gif][stability graph]]. <img width="596" alt="I/V characteristics of all sensors" src="%PUBURL%/DetDev/MCMD/w09_IVSummary.gif" height="372" /> <img width="596" alt="Summary of all C/V on wafer 09" src="%PUBURL%/DetDev/MCMD/w09_CVSummary.gif" height="372" /> <img width="596" alt="1/C² vs V graphs for all sensors on w09" src="%PUBURL%/DetDev/MCMD/w09_1_C2vsV_Summary.gif" height="372" /> <img width="596" alt="Rs vs V summary graph" src="%PUBURL%/DetDev/MCMD/w09_RsVSummary.gif" height="372" /> <img width="596" alt="" src="%PUBURL%/DetDev/MCMD/w09I400Map.gif" height="372" /> *Depletion voltage extracted from C/V* The depletion voltage was extracted by fitting two first order polynomials to the 1/C2 vs. Vbias graph. The first straight line is fitted between 0 and 30 V and the second straight line is fitted between 150 and 400 V. The depletion voltage is defined as the intersection between these two lines. The depletion voltage is displayed both as a histogram and as a map where the depletion voltage is displayed in its position on the wafer, with coordinates as defined in the figure above. The depletion voltage could not be determined for X5Y3 due to its breakdown, hence the histograms include 25 sensors. <img width="596" alt="Wafer map of depletion voltages" src="%PUBURL%/DetDev/MCMD/w09_VdepMap.gif" height="372" /> <img width="596" alt="Histogram of measured depletion voltages" src="%PUBURL%/DetDev/MCMD/w09_VdepHisto.gif" height="372" /> ---++++ ---++++ *Summary plots of I/V and C/V performance for wafer 14 (6 µm BCB)* Until present 19 sensors have been teste of which 18 are inclueded in the plots. Sensor X0Y4 broke down a very low voltage and is excluded from the analysis presented here. <img width="596" alt="I/V characteristics of all sensors" src="%PUBURL%/DetDev/MCMD/w14_IVSummary.gif" height="372" /> <img width="596" alt="Summary of all C/V on wafer 09" src="%PUBURL%/DetDev/MCMD/w14_CVSummary.gif" height="372" /> <img alt="1/C² vs V graphs for all sensors on w09" src="%PUBURL%/DetDev/MCMD/w14_1_C2vsV_Summary.gif" /> <img width="596" alt="Rs vs V summary graph" src="%PUBURL%/DetDev/MCMD/w14_RsVSummary.gif" height="372" /> <img width="596" alt="" src="%PUBURL%/DetDev/MCMD/w14I400Map.gif" height="372" /> <img width="596" alt="" src="%PUBURL%/DetDev/MCMD/w14I600Map.gif" height="372" /> *Depletion voltage extracted from C/V* The depletion voltage was extracted by fitting two first order polynomials to the 1/C2 vs. Vbias graph. The first straight line is fitted between 0 and 30 V and the second straight line is fitted between 150 and 400 V. The depletion voltage is defined as the intersection between these two lines. The depletion voltage is displayed both as a histogram and as a map where the depletion voltage is displayed in its position on the wafer, with coordinates as defined in the figure above. Sensor X0Y4 is not inclued in the depletion voltage plots since it broke down at low voltages. <img width="596" alt="Wafer map of depletion voltages" src="%PUBURL%/DetDev/MCMD/w14_VdepMap.gif" height="372" /> ---++++ <img width="596" alt="Histogram of measured depletion voltages" src="%PUBURL%/DetDev/MCMD/w14_VdepHisto.gif" height="372" /> *I/V ramp to 1000 V for two sensors on w14* <img width="596" alt="I/V up to 1000V for two sensors" src="%PUBURL%/DetDev/MCMD/w14_IV_1000V.gif" height="372" /> Sensor X5Y1 was kept at 1000V and a break down started to develop at which point it was ramped down immediately ---++++ <img width="596" alt="kkk" src="%PUBURL%/DetDev/MCMD/w14X5Y1_Istability.gif" height="372" /> ---++++ Plots combining the I/V and C/V data for wafer 09 and 14 <img width="596" alt="Combined depletion voltages for wafer 09 nad 14" src="%PUBURL%/DetDev/MCMD/combined_Vdepl.gif" height="372" /> The following plot show the reverse current at 400 V bias for all measured sensors on wafer 09 and 14. <img width="596" alt="current at 400 V for all sensors on w 09 and w 14" src="%PUBURL%/DetDev/MCMD/combined_I400.gif" height="372" /> The following plot shows the reverse current at 400 and 600 V for w 14 for all measured sensors <img width="596" alt="Current at 400 and 600 V for w14" src="%PUBURL%/DetDev/MCMD/combined_Iw14.gif" height="372" /> -- Main.LarsEklund - 16 Dec 2008
E
dit
|
A
ttach
|
Watch
|
P
rint version
|
H
istory
: r1
|
B
acklinks
|
V
iew topic
|
Ra
w
edit
|
M
ore topic actions
Topic revision: r1 - 2008-12-16
-
LarsEklund
DetDev
Log In
or
Register
DetDev Web
Create New Topic
Index
Search
Changes
Notifications
RSS Feed
Statistics
Preferences
Webs
ATLAS
PUUKA
DetDev
Gridmon
IT
LHCb
LinearCollider
Main
NA62
Sandbox
TWiki
Copyright © 2008-2025 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki?
Send feedback