Line: 1 to 1 | ||||||||
---|---|---|---|---|---|---|---|---|
Inter-strip capacitance measurments | ||||||||
Line: 11 to 11 | ||||||||
Capacitance between one central strip to its two neighbours vs. bias voltage for 100 kHz and 1 MHz | ||||||||
Changed: | ||||||||
< < | All measurements done with a 1 MOhm resistor and an ampere meter connected between the bias rail and the HV return, exept for the measurement of X5Y1 that gives a lower interstrip capacitance. | |||||||
> > | All measurements done with 1 Mohm resistor and an ampere meter connected between the bias rail and the HV return (ground) except for the measurement X5Y1/2 where bias rail was connected directly to the ground | |||||||
![]() | ||||||||
Line: 19 to 19 | ||||||||
Time evolution of the capacitance of one strip to its two neighbours at 600 V | ||||||||
Changed: | ||||||||
< < | All measurements done with a 1 MOhm resistor and an ampere meter connected between the bias rail and the HV return, exept for the measurement of X5Y1 that gives a lower interstrip capacitance. | |||||||
> > | All measurements done with 1 Mohm resistor and an ampere meter connected between the bias rail and the HV return (ground) except for the measurement X5Y1/2 where bias rail was connected directly to the ground | |||||||
![]() |