Difference: KinematicCutsConstraints (6 vs. 7)

Revision 72013-03-06 - DominicSmith

Line: 1 to 1
 
META TOPICPARENT name="Main.DominicSmith"

Constraints from "Higgs mass and Cross-Section Measurements at a 500GeV CLIC Machine, Operating at sqrt(s)= 350GeV and 500GeV"

Line: 103 to 103
 where Ns is the number of events of Higgs-strahlung signal, e is the total efficiency of signal reconstruction, and L is the luminosity.
Added:
>
>
Signal & Background Analysis

Number of events run over: 5000

mumuX

  • Signal underflow : 0
  • Signal overflow: 435
90.5% of entries used.

  • Background underflow : 174
  • Background overflow : 313
35% of entries used.

eeX

  • Signal underflow : 47
  • Signal overflow : 591
86.21% of entries used.

  • Background underflow : 299
  • Background overflow : 303
40.39% of entries used.

Number of events run over: 50,000

mumuX

  • Signal underflow : 7
  • Signal overflow : 4565
90.01% of entries used.

  • Background underflow : 1720
  • Background overflow : 3077
34.56% of entries used.

eeX

  • Signal underflow : 500
  • Signal overflow : 5615
86.88% of entries used.

  • Background underflow : 3119
  • Background overflow : 2985
41.61% of entries used.

 
Eta-Phi plots

The momentum of each particle produced in a collision can be decomposed in:

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2025 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback