---++ Via yield measurements of Run 1 ---+++ Measurements of w04 (12 um BCB, mechanical) *Probing double vias on same pad:* 24 sensors * 4 pads * 2 vias = 192 vias No via failures observed Measurement offset: 2.3 ohm (both needles on the same pad) Measured resistance: average = 4.5 ohm, sigma = 0.65 *Probing the two vias to the bias rail:* 26 sensors * 2 vias = 52 vias No via failures observed Measurement offset: 2.3 ohm (both needles on the same pad) Measured resistance: average = 17.5 ohm, sigma = 0.66 *Cp-Rp measurement:* Checking for opens and shorts 26 sensors * 120 vias = 3120 vias (no opens seen) 26 sensors * 60 pairs = 1560 pairs (no shorts seen) -- Main.LarsEklund - 16 Dec 2008