Difference: MCMDCsG (2 vs. 3)

Revision 32009-04-06 - LarsEklund

Line: 1 to 1
 
META TOPICPARENT name="MCMD"

Measurement of capacitance between strip and GND plane

Line: 20 to 20
  Cs for all sensors and all frequencies
Changed:
<
<
Table with calculated strip to GND plane capacitance for w14
GND plane type
# strip covered
Cs/strip
Rs/strip
Solid 129 1.85 pF
Mesh 50%/30um
128.5 1.30 pF
Mesh 50%/80um 126 1.5 pF
Mesh 25%/30um 126.5 0.76 pF
>
>
Table with calculated strip to GND plane capacitance for w14 at 10 kHz
GND plane type
# strip covered
Cs/strip
Rs/strip
Solid 129 1.85 pF
Mesh 50%/30um
128.5 1.30 pF
Mesh 50%/80um 126 1.5 pF
Mesh 25%/30um 126.5 0.76 pF
 

Results for w09, 12 um BCB under the GND plane

-- LarsEklund - 02 Apr 2009

 