Line: 1 to 1 | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measurement of capacitance between strip and GND plane | |||||||||||||||||||||
Line: 8 to 8 | |||||||||||||||||||||
The impedance between the bias rail and the ground plane was measured with an LCR meter in RsCs mode for a range of frequencies. For reasonably low frequencies, the measured Rs is all the bias resistances in parallel. And the measured Cs is all the strip to ground plane couplings in parallel. The measurements were done with the sensor biased for at least one sensor of each ground plane type.
Results for w14, 6 um BCB under the GND plane | |||||||||||||||||||||
Added: | |||||||||||||||||||||
> > | Capacitive coupling between bias rail and GND plane versus bias voltage | ||||||||||||||||||||
![]() | |||||||||||||||||||||
Added: | |||||||||||||||||||||
> > | Capacitive coupling between bias rail and GND plane versus time
![]() ![]()
Results for w09, 12 um BCB under the GND plane | ||||||||||||||||||||
-- LarsEklund - 02 Apr 2009
|
Line: 1 to 1 | |||||||||
---|---|---|---|---|---|---|---|---|---|
Added: | |||||||||
> > |
Measurement of capacitance between strip and GND planeMeasurements performed by Alex Chilingarov at Lancaster UniversityIntroductionThe impedance between the bias rail and the ground plane was measured with an LCR meter in RsCs mode for a range of frequencies. For reasonably low frequencies, the measured Rs is all the bias resistances in parallel. And the measured Cs is all the strip to ground plane couplings in parallel. The measurements were done with the sensor biased for at least one sensor of each ground plane type.Results for w14, 6 um BCB under the GND plane![]()
|